IGUS CFBUS.045 cable - (4x(2x0.15))C

Brand: Igus
Product Code: MX-CFBUS-045
Availability: Temporarily Out Of Stock
26.60€
Ex Tax: 21.98€


CFBUS.045 cable
  • to maximum load requirements
  • Outer shell made of thermoplastic elastomer
  • shielded
  • Oil resistant
  • resistant to bio-oil
  • does not sustain combustion
  • resistant to hydrolysis and microorganisms

Chainflex® cable classification:
Class 6.5.4
Load:
6: Cables designed for continuous movement in cable guides under heavy load. radii from 5 x diameter. speed up to 10 m/s
Stroke Length:
5: Travels up to 400 m and more
Oil resistance:
4: Oil resistance in accordance with DIN EN 60811-2-1. resistance to bio-oil according to VDMA 24568 with Plantocut 8 S-MB by DEA

Vein Stranded cable in a version that is particularly resistant to bending, made of thin. bare copper conductors (according to EN 60228)
Core insulation 182.001 according to the specification for profibus cables. 182.045 according to the specification for Ethernet cables.
Vein twist 182.001 in the Profibus standard with aramid load-bearing elements. 182.045 in the Ethernet standard with aramid load-bearing elements
Vein marking according to rail specification. see product selection
Inner cover TPE mixture adapted to the requirements of E-Chain® chains.
Full screen Extremely resistant to bending. tin coated braided copper screen. Coverage approximately 70% linear. approx. 90% optical
Outer coat Low-adhesive. Particularly abrasion-resistant and highly flexural-resistant TPE-based compound suitable for the requirements of E-Chain®.
Color: red-lilac (similar to RAL 4001)
temperature range in motion: From -20°C to +70°C. bending radius min. 10 xd
Temperature range after installation From -40°C to +70°C. bending radius min. 5 xd
v max. self-supporting/gliding 10 m/s. 6 m/s
a max. 100 m/s²
Travel path Suspended applications up to 50 m
resistant to UV radiation BFOC(ST) connectors with conversion to SC on both ends
Nominal voltage 30 May
Test voltage 500V
Oil Oil-resistant (according to DIN EN 50363-10-2).
does not sustain combustion in accordance with IEC 60332-1-2. CEI 20-35. FT1. VW-1
No silicone Free from substances that negatively affect the adhesion of paint (according to PV 3.10.7 - status from 1992).
Halogen free According to EN 50267-2-1.
UL/CSA products for use at sea
CEI Based on CEI 20-35
CE Based on 2006/95/EC
Lead-free In accordance with (RoHS) 2002/95/EG.
Clean rooms Complies with ISO Class 1. The outer material of the shirt complies with CF27.07.05.02.01.D. tested
by IPA in accordance with standard 14644-1
CTP C-DE certificates. PB49.B.00416
EAC TC RU C-DE certificates. ME77.B.01218
GL Certificate compliant with GL type tests - certificate no.: 61 937-14 HH


Typical use of the cable
  • to maximum load requirements
  • Virtually complete resistance to oils. even organic oils
  • Use indoors and outdoors without direct sunlight
  • Especially for unsupported and sliding travel distances of up to 400 m.
  • busbar cables for storage and retrieval units in high-bay warehouses. machining equipment/tools. quick service. clean rooms. semiconductor assembly. cranes for indoor work and for use at low temperatures