Cable CF38.100.03.O.PE - (3 x 10.0)C
Ex Tax: 52.81€
Cable CF38.100.03.O.PE
- For heavy loads
- Outer shell made of thermoplastic elastomer
- shielded
- Oil resistant
- resistant to bio-oil
- PVC and halogen free
- resistant to UV radiation
- resistant to hydrolysis and microorganisms
Removing cable sheaths 50% faster
► CFRIP
Chainflex® cable classification:
Class 7.5.4
Load:
7: Cables for continuous movements in energy chains under heavy loads and with the smallest turning radii. for indoor and outdoor applications. radii from 4 x diameter. speed up to 10 m/s and compliance with other requirements
Stroke Length:
5: Travels up to 400 m and more
Oil resistance:
4: Oil resistance in accordance with DIN EN 60811-2-1. resistance to bio-oil according to VDMA 24568 with Plantocut 8 S-MB by DEA
temperature range in motion: | From -35°C to +90°C. bending radius min. 7.5 xd | |
Temperature range after installation | From -40°C to +90°C. bending radius min. 4 xd | |
v max. self-supporting/gliding | 10 m/s. 6 m/s | |
a max. | 80 m/s² | |
Travel path | For unsupported and sliding travel up to 400 m and more. class 4 | |
resistant to UV radiation | BFOC(ST) connectors with conversion to SC on both ends | |
Nominal voltage | 600/1000 V (based on DIN VDE 0250) | |
Test voltage | 4000 V (based on DIN VDE 0281-2) | |
Oil | Oil-resistant (according to DIN EN 60811-2-1). resistant to organic oils (according to VDMA 24568 with Plantocut 8 S-MB tested by DEA). class 4 | |
No silicone | Free from substances that negatively affect the adhesion of paint (according to PV 3.10.7 - status from 1992). | |
Halogen free | According to EN 50267-2-1. | |
Vein | < 10 mm²: Stranded conductor with a very flexible structure made of uninsulated copper conductors (according to the PN-EN 60228 standard) ≥ 10 mm²: conductor made of pre-wires (according to PN-EN 60228) | |
Core insulation | high mechanical quality TPE mixture with extremely low capacitive reactance | |
Vein twist | cores twisted with a short pitch over the core ensuring tensile strength | |
Vein marking | Power cable: Black cores with white numbers. one green/yellow core 1. Core: U / L1 / C / L+ 2. Core: V/L2 3. Core: W/L3/D/L- 4. Core: 4/N | |
Inner cover | TPE mixture adapted to the requirements of E-Chain® chains. | |
Full screen | Extremely resistant to bending. tin coated braided copper screen. Coverage approximately 70% linear. approx. 90% optical | |
Outer coat | Low-adhesive. Particularly abrasion-resistant and highly flexural-resistant TPE-based compound suitable for the requirements of E-Chain®. Color: black (similar to RAL 9005) | |
CFRIP tear strip | Quick sheath removal: CFRIP tear strip in the inner sheath | |
CE | Based on 2006/95/EC | |
Lead-free | In accordance with (RoHS) 2002/95/EG. | |
Clean rooms | Complies with ISO Class 1. The outer material of the shirt complies with CF9.15.07. IPA tested according to standard 14644-1 | |
EAC | TC RU C-DE certificates. ME77.B.01255 |
Typical use of the cable
- to maximum load requirements
- Virtually complete resistance to oils. even organic oils
- for indoor and outdoor use. UV resistant
- Especially for unsupported and sliding travel distances of up to 400 m and more.
- storage and retrieval units in high-bay warehouses. machining equipment/tools. fast service. clean rooms. semiconductor assembly. ship-shore. outdoor cranes. use at low temperatures